Available in multiple designs...

FastScan-F114 represents a new generation of CCD cameras combining the superior quality of a slow scan CCD camera with the fast frame rate of a video camera. Various mechanical designs make it suitable to almost all TEMs, even when using various accessories such as PEELS, post-column energy filters, STEM detectors or wide-angle cameras. The frame transfer CCD chip allows the FastScan-F114 to operate without beam shutter.

Download product info (PDF, 3.2 MB)

 

  Tiling
    Live image functions
  Tiling extends the field-of-view of your camera. Automatic acquisition and pixel accurate assembly with compensation of intensity variations generate a large seamless image from a set of single exposures.     The video recorder option of EM-Menu 4 provides real-time (up to 27 fps) displaying of images and power spectra, and storing video sequences as movie or single frames, enabling high-end video microscopy for in situ applications.

 

  Fiber optical coupling
    Optimized scintillators
  Fiber optical coupling of the electron sensitive layer (scintillator) with the CCD sensor increases the amount of light collected in comparison with lens-optical coupling and, as a result, the sensitivity of the camera. The tapered fiber optics enlarges the field of view to 29 x 29 mm² and increases the resolution.     TVIPS optimizes the scintillator for individual demands. Resolution and sensitivity can be customized for high tensions up to 400 kV.

 

Optional fiber optical coupling with a 2:1 tapered fiber optics (FastScan-F114T)

 

Optional fiber optical coupling with a 2:1 tapered fiber optics (FastScan-F114T). The tapered fiber optics enlarges the field of view to 29 x 29 mm² and increases the resolution.

 

Multiple Designs

 

The FastScan-F114 is available in the following designs:

  • F114 on-axis, 1:1 fiberoptics, available for all TEMs with adaptors in the bottom plate
  • F114T on-axis, 2:1 taper, available for all TEMs with an opening of at least 45 mm diameter in the bottom plate
  • F114TR is a retractable camera with a 2:1 tapered fiber optics, located in the camera chamber (available for JEOL microscopes only)
  • F114SX on-axis, 1:1 fiberoptics, available for specials adaptors
  • F114NX near-axis, compatible with post-column filters, PEELS, or other TVIPS on-axis cameras
  • F114FX off-axis, compatible with post-column filters, PEELS, or on-axis cameras (FEI/Philips only)

 

 
SPECIFICATIONS
FastScan-F114   -F114NX   -F114T  
  CCD type (architecture) Frame transfer  
  CCD format (pixel) 1024 x 1024  
  CCD pixel size (μm) 14 x 14  
  Field of view (mm) 14,3 x 14,3   14,3 x 14,3   28,6 x 28,6  
  Readout rate @ 12 bit 20 Mpixel/sec  
  Frame rate at full resolution 12 frames/sec  
  Frame rate at 2 x binning 26 frames/sec (image size 512 x 512 pixels)  
  Post-magnification 1.1 x - 1.5 x  
  Electron-optical coupling 1:1 fiber-optics   1:1 fiber-optics   2:1 taper  
  Scintillator type polycrystalline phosphor  
  Sensor cooling < -10˚ C, regulated  
  Binning factors
1 x, 2 x  
  Gain factors (analog) 1 x  
  Full well capacity (electrons)* 230 000  
  Dynamic range* 2 500:1 (maximum/noise)  
  Non-linearity (after flatfield correction)* < 2 %  
  Sensitivity for primary
electrons (120kV scintillator)*
3.0 counts   3.0 counts   1.5 counts  
  SNR (for single
120 keV electrons)*
3.0   3.0   1.5  
  Resolution
(NTF at Nyquist frequency) *
> 10 %   > 10 %   > 13 %  
  Anti-blooming yes  
  Bottom mounted on-axis   near-axis   on-axis, rotatable  
  System requirements Windows 2000 / XP, PCI interface or Firewire  
  Options EM-Menu Image Processing software, Tomography  
  * Typical values