Slow scan CCD camera (4k, 15 μm, 16 bit)

TemCam-F415MP is a 4k x 4k TVIPS camera with an active area of 61 mm x 61 mm, moving into dimensions which have been limited to film so far. It is the perfect solution for all kinds of high resolution applications in materials and life science. TemCam-F415MP is available with multiport readout (4 x 1 MHz). High quality 16 bit analog-to-digital converters guarantee maximum performance.

Download product info (PDF, 1.7 MB)

 

  CCD cooling
    Optimized scintillators
  For optimum performance, the Peltiercooled CCD chip (regulated at -25°C) is located in a vacuum housing separated from the microscope vacuum. The scintillator surface is kept close to room temperature. This design avoids contamination and allows venting the camera chamber without turning off the CCD camera.     TVIPS optimizes the scintillator for individual demands. Resolution and sensitivity can be customized for high tensions up to 400 kV. Two standard types are available: optimized for high resolution (HR) or for high sensitivity (HS).

 

  Fiber-optical coupling
    Near-axis flange
  Fiber optical coupling of the electron-sensitive polycrystalline phosphor layer (scintillator) with the CCD sensor increases the amount of light collected in comparison with lens-optical coupling and, as a result, the sensitivity of the camera. This design results in a significant discrimination of single electron events which is important for low dose application.     TVIPS has designed a special flange which combines TemCam-F415MP/F224HD with FastScan-F114NX, a high-quality fiber-optically coupled CCD camera operating at video rate. Due to disadvantages of side-mounted cameras, this is an interesting option to monitor the TEM image and its power spectra in real-time, for the main purpose of alignment, demonstration or low dose search.

 

 
SPECIFICATIONS
TemCam-F415MP  
  CCD type (architecture) Full frame  
  CCD format (pixels) 4096 x 4096  
  CCD pixel size (μm2) 15 x 15  
  Field of view (mm2) 61.4 x 61.4  
  Readout rate @ digitization 4 x 1 Mpixel/sec @ 16 bit  
  Frame rate at full resolution 0.15 (6 secs)  
  Frame rate at 2 x binning 0.4 frames/sec  
  Post-magnification 1.4 x - 1.7 x  
  Electron-optical coupling 1:1 fiber-optics  
  Scintillator type Polycrystalline phosphor  
  CCD cooling < -25˚ C, regulated  
  CCD binnig factors 1 x, 2 x, 4 x, 8 x  
  Gain factors (analog) 1 x, 2 x, 4 x  
  Full well capacity (CCD electrons)* 100 000  
  Dynamic range (maximum/noise)* 7500:1**  
  Non-linearity* < 1 %  
  Sensitivity for primary
electrons (120 kVscintillator)*
50 counts***  
  SNR (for single
120 keV electrons)*
> 10:1  
  Resolution
(NTF at Nyquist freq.)*
> 12 %  
  Anti-blooming yes  
  Bottom mounted on-axis  
  System requirements Windows XP, PCI interface  
  Options FastScan-114NX in near-axis position, motorized beam stop  
  Software EM-Menu 4, Tomography, Single Particle Data Collection  